Since the PZEM-017 uses the standard Modbus RTU protocol, you can use professional simulators. Modbus Poll or QModBus.
This guide provides everything you need to locate, download, and install the PZEM-017 software. Direct Links and Software Options
💡 If you plan on long-term data logging, skip the factory software and use Grafana with InfluxDB via a Raspberry Pi for professional-grade power monitoring.
Depending on your technical comfort level, there are three primary ways to interface with the PZEM-017: 1. Official Peacefair Factory Software
Ensure you are using a high-quality USB cable. Cheap clones often drop connection.
The PZEM-017 is a popular DC communication module used for measuring voltage, current, power, and energy in solar systems, battery banks, and industrial setups. To unlock its data logging capabilities on a PC, you need the correct software and drivers.
Click "Connect" or "Start" to begin the data stream. Troubleshooting Common Issues
Connect the PZEM-017 to your DC source (0-300V) and the external shunt. Connect the RS485 terminals (A and B) to your USB-to-RS485 adapter. Install Driver: Run the CH340 or CP2102 driver installer. Run Software: Open the PZEM-017 Master software. Configure Port: Select the correct COM Port (found in Device Manager). Set Baud Rate to 9600. Set Modbus Address (Default is 0x01).
Since the PZEM-017 uses the standard Modbus RTU protocol, you can use professional simulators. Modbus Poll or QModBus.
This guide provides everything you need to locate, download, and install the PZEM-017 software. Direct Links and Software Options
💡 If you plan on long-term data logging, skip the factory software and use Grafana with InfluxDB via a Raspberry Pi for professional-grade power monitoring. pzem-017 software download
Depending on your technical comfort level, there are three primary ways to interface with the PZEM-017: 1. Official Peacefair Factory Software
Ensure you are using a high-quality USB cable. Cheap clones often drop connection. Since the PZEM-017 uses the standard Modbus RTU
The PZEM-017 is a popular DC communication module used for measuring voltage, current, power, and energy in solar systems, battery banks, and industrial setups. To unlock its data logging capabilities on a PC, you need the correct software and drivers.
Click "Connect" or "Start" to begin the data stream. Troubleshooting Common Issues Direct Links and Software Options 💡 If you
Connect the PZEM-017 to your DC source (0-300V) and the external shunt. Connect the RS485 terminals (A and B) to your USB-to-RS485 adapter. Install Driver: Run the CH340 or CP2102 driver installer. Run Software: Open the PZEM-017 Master software. Configure Port: Select the correct COM Port (found in Device Manager). Set Baud Rate to 9600. Set Modbus Address (Default is 0x01).